Backup energy calculator

Choose essential loads and their operating hours. Energy and starting demand are checked separately.

Appliance 1
Appliance 2
Appliance 3
Appliance 4
Appliance 5

System assumptions

Results update automatically

Continuous load

245 W

Estimated load surge

545 W

Load energy

1.2 kWh

Battery — required usable energy

1.3 kWh

Battery — nominal energy

1.64 kWh

Inverter — continuous output

400 W

Inverter — surge output

600 W

Find Matching Equipment

How this is calculated

We sum power × quantity × each appliance’s operating hours, capped at the backup duration. Usable battery energy accounts for inverter losses; nominal energy also includes discharge reserve. Inverter continuous output includes 25% margin and surge 10%.

Continuous load assumes enabled appliances run together; surge adds simultaneous starts, a conservative scenario. Refrigerator hours mean actual compressor operating time. Use measurements and manufacturer data.

Final selection and installation must be checked by a qualified electrician against manufacturer instructions and applicable electrical requirements. Never backfeed house wiring through a socket with a generator or inverter.